The Points During Installation Work of Flow Meter

Flow meter is one of the components of metering scientific technology, which has a close relation with national economy、the building up of national defense and scientific research. To have this work done well is crucial to ensure the quality of products and the improvement of production efficiency as well as the development of boosting the science and technology, especially in the current era when the energy crisis emerges and the degree of industrial automation gets higher. In short, flow meter plays an essential role in national economy obviously.

Flow meter
Flow meter is widely applied in all fields of national economy including metallurgy、electric power、coal、chemical industry、oil、transportation、construction、textile、food、medicine、agriculture、environmental protection and people’s daily life, which occupies an important place in developing agricultural production、saving energy、improving the quality of products、increasing economic benefits and the management level. Next, let’s introduce eight key points during installation work briefly:

1. The requirement of the outer environment:


Flow meter had better be installed indoor. While it has to be installed outdoor, we must take some measures to protect it from the sun、the rain and the lightning in case of affecting its service life. Flow meter should be installed on the place where is handy to be repaired without strong electromagnetic inference and thermal radiation.

2. The requirement of by—pass pipe.


In order to ensure the regular production when checking and repairing the flow meter, we have to install shut—off valve( cut—off valve) in the front of and in the rear of the pipe. At the meantime, we should set by—pass pipe. Flow control valve should be installed on the downstream of the flow meter. When using the flow meter, the cut—off valve fixed on the upstream have to be fully open so as not to produce the unsteady flow phenomenon by the liquid in the parts of upstream.

Flow meter 2

3. The requirements of straight length.


It is necessary to mount the flow meter horizontally on the pipe ( the pipe tilts within 50). The axe of flow meter should be centric with the one of the pipe when installing the flow meter to make the consistent flow. The length of the pipe of upstream of flow meter should not less than the equal channel straight length which is 2D. As for the bore size that is contained in tubing from the downstream and the upstream of mounting point of flow meter has to be the same as the flow meter's.

4. The requirements of medium contain the impurities.


For the sake of promising the service life of flow meter, we should install a filter before its straight length.

5. The requirements of installing wielding


When installing wielding(such as vortex shedding flow meter), the users need to another a pair of standard flange wielding in the front or in the rear of the pipe. It is not allowed to have it with flow meter. During the installation, the sheet gasket of flange wielding should not concave into the pipe. Before the installation, the foul in the pipe like wielding slag should be cleared away strictly. When it comes to the foul like fragments、wielding slag、rocks and dust, we should use the 5 micrometers’ automatic filter installed on the upstream which aims to stop the drops and grain of sands. We had better substitute the flow meter with the equal channel pipe to blow and sweep to prohibit the flow meter from being destroyed in the process of use.

6. The requirements of flow meter grounding.


Flow meter can be connected with the ground but it can not be share with the ground electrode of the heavy current system.

7. The requirements of the explosion—proof products


To make sure that the flow meter(such as electromagnetic flow meter) to be used safely and normally, we should double check whether the using environment of explosion—proof flow meter conforms to the regulations and requirements set for the corresponding users. Also, during the process of installing and applying, we should strictly obey the national operating requirements towards explosion—proof products. The users can not change the attended mode of explosion—proof system at our discretion nor switch the instrument at will. 

8. The requirements of the flow range


Model selection should be within the regulated range flow and to stop over speeding to gain the ideal accuracy and guarantee its normal service life. 

Electromagnetic Flowmeter

  • Liquid Turbine Flow Meter

    Liquid Turbine Flow Meter
    Liquid Turbine Flow Meter OverviewSLW series Turbine Flow Meter has simple structure, light weight, high-accuracy, perfe...
  • Vortex Flow Meter

    Vortex Flow Meter
    Overview of Vortex Flow MeterSTLU series smart vortex flow meter is mainly used for measuring flow of industrial pipelin...

Description of Electromagnetic Flowmeter

Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.
Magnetic inductive flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Mag meter is industrial flow meter; it can be used in environmental protection, metallurgy, pharmaceutical, paper making, water supply (magnetic water meter) etc.
Besides measuring flow of general conductive liquid, magnet meter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali to be used as chemical flow meter, sanitary flow meter or sewage flow meter. We are supplier for full bore  electromagnetic flow meter.
As China magnetic flow meter manufacturer, the magnetic flow meter price is reasonable, custom magnetic meter also with fast delivery time due to abundant flow meter spare parts in our warehouse.

Electromagnetic Flowmeter Technical Parameters




Picture
full bore magnetic flow meter
electromagnetic flow meter
magmeter flow meter
electromagnetic flow sensor
Model
SE 11
Standard
SE12
High Accuracy
SE13
Sanitary
SE14
Insertion type
Medium
Conductivity Fluids
Accuracy
±0.5%
±0.25%
±0.5%
±1.5%
Repeatability
±0.25%
±0.125%
±0.25%
±0.75%
Fluid Temperature
-25°C ~ 130 °C
-25°C ~ 130 °C
-25°C ~ 130 °C
-25°C ~ 130 °C
Conductivity
≥ 5μs/cm ( soft water should be ≥ 20μs/cm)
Size
10~2000 mm
10~2000 mm
10~125 mm
200~3000 mm
Operation Pressure
0.6Mpa/1.0Mpa/1.6Mpa/2.5Mpa/4.0Mpa/Others
Velocity
0.5 m/s ~ 10 m/s
Flow Direction
Forward / Reversed
Electrodes Material
316L / Hastelloy C2,B4/Tantalum/Titanium/Platinoiridita/others
Liner Material
Rubber /PTFE/PFA
PFA
PTFE
Electrodes Type
Standard
Qty of Electrodes
2 pairs
( one pair for measuring, one pair for grounding)
1pair ( measuring)
Tube Material
304 Stainless Steel
Flange Material
Carbon steel/304 Stainless steel
304 Stainless steel
304 Stainless steel
Installation Type
Flange
Tri-clamp/screw
Flange/plug-in
Protection level
IP65/P68 ( Remote Version)
Power
220VAC ±20% 60HZ  /  24 VDC
Signal Output
4~20mA
Communication
Hart / Modbus/ Profibus
Electrical connection
2* M20 * 1.5
Explosive-Proof
Exd eia II C T3~T6
Construction Type
Compact / Remote
Operation Environment
Magnetic flow meters Operation
Environment temperature:-25 °C~ + 60 °C; Relative Humility: 5% ~90%

Electromagnetic Flowmeter Flow Range

Size(DN)
Pressure
Min flow range
velocity(0-0.5)m/s
Max Flow range
velocity(0-10)m/s
10
4.0 Mpa
(0-2.25)L/min
(0-45)L/min
15
4.0 Mpa
(0-5)L/min
(0-100)L/min
20
4.0 Mpa
(0-7.5)L/min
(0-150)L/min
25
4.0 Mpa
(0-10L)/min
(0-200)L/min
32
4.0 Mpa
(0-20L)/min
(0-400)L/min
40
4.0 Mpa
(0-30L)/min
(0-600)L/min
50
4.0 Mpa
(0-3)m³/h
(0-60)m³/h
65
4.0 Mpa
(0-6)m³/h
(0-120)m³/h
80
4.0 Mpa
(0-9)m³/h
(0-180)m³/h
100
1.6 Mpa
(0-12)m³/h
(0-240)m³/h
125
1.6 Mpa
(0-21)m³/h
(0-420)m³/h
150
1.6 Mpa
(0-30)m³/h
(0-600)m³/h
200
1.6 Mpa
(0-54)m³/h
(0-1080)m³/h
250
1.6 Mpa
(0-90)m³/h
(0-1800)m³/h
300
1.0 Mpa
(0-120)m³/h
(0-2400)m³/h
350
1.0 Mpa
(0-165)m³/h
(0-3300)m³/h
400
1.0 Mpa
(0-225)m³/h
(0-4500)m³/h
500
1.0 Mpa
(0-330)m³/h
(0-6600)m³/h
600
1.0 Mpa
(0-480)m³/h
(0-9600)m³/h
700
1.0 Mpa
(0-660)m³/h
(0-13200)m³/h
800
1.0 Mpa
(0-900)m³/h
(0-18000)m³/h
900
1.0 Mpa
(0-1200)m³/h
(0-24000)m³/h
1000
1.0 Mpa
(0-1350)m³/h
(0-27000)m³/h
1200
0.6 Mpa
(0-2100)m³/h
(0-42000)m³/h
1400
0.6 Mpa
(0-2700)m³/h
(0-54000)m³/h
1600
0.6 Mpa
(0-3600)m³/h
(0-72000)m³/h
1800
0.6 Mpa
(0-4500)m³/h
(0-90000)m³/h
2000
0.6 Mpa
(0-5700)m³/h
(0-114000)m³/h

Electromagnetic Flowmeter Model Selection


Item
Code
Description
Factory Mark
SHD
Silver Automation Instruments
Meter Type
SE11
Standard ( 0.5% accuracy ,DN10~DN2000)
SE12
High Accuracy (0.25% accuracy,DN10~DN2000)
SE13
Sanitary type (0.5% accuracy,DN10~DN125,Tri-clamp )
SE14
Insertion type  (1.5% accuracy,DN200~3000)
Meter Size
-XXX
Example:100=DN100,refer to Table 2 Nominal diameter,
pressure and flow range
Electrode Material
E0
316L SS
E1
Hastelloy B
E2
Hastelloy C
E3
Titanium
E4
Tantalum
E5
Pt/Iridium Alloy
Liner Material
L1
Teflon (PTFE)
L2
F46 (FEP)
L3
PFA
L4
Hard rubber
Rated Pressure
1G
GB1.6Mpa
1D
DIN PN16
1A
ANSI 150#
2G
GB2.5Mpa
2D
DIN PN25
2A
ANSI 300#
3G
GB4.0Mpa
3D
DIN PN40
3A
ANSI 600#
S
Special
Working Temperature
E
<60 °C
H
60~160 °C
Protection Grade
P0
IP65
P1
IP 67
P2
IP68  (only for remote version, sensor IP68,converter IP65)
Converter Type
0
Compact
1
Remote (standard cable 5 meters)
Output
Signal Communication
S0
4~20mA
S1
RS-485
S2
Hart
S3
Profibus-DP*1
S4
Pulse Output
Housing Material
H0
Carbon steel
H1
304 SS
H2
Special Demand
Material of Body Flange
F0
Carbon steel
F1
304 SS
F2
Special Demand
Power Supply
G0
220V AC (85~265V,45~63 Hz)
G1
24V DC (18~36V)
G2
Battery supply (without 4~20mA output)
Explosion Proof
0
Non(0 could be omitted)
Ex
Exd eia II C T3~T6

Welcome to send your specific parameters to us, we will evaluate and choose proper type magnetic flow meter and provide best electromagnetic flow meter price to you.

评论

此博客中的热门博文

The Model Selection of Mag Meter& Mag Flow Meter Price

What applications do flow meters usually used?

Coriolis mass flow meters for batch sucrose solution Applications