Attention in the Installation Process of Flow Meter

The flow metrology is one of the components of measurement science and technology, which has a close relation with the national economy, national defense construction, and scientific research. Doing this work well has an important role in ensuring product quality, improving production efficiency and promoting the development of science and technology. Particularly in nowadays, energy crisis and the deep of industrial production automation, the status and role of the flow meter in the national economy is more and more evident.

The flow meter is widely used in various areas of the national economy like metallurgy, electric power, coal, chemical industry, petroleum, transportation, construction, textile, food, medicine, agriculture, environmental protection and people's daily life. It is an important tool which occupies a vital position in developing industrial and agricultural production, saving energy, improving product quality, improving economic efficiency and management level. Here is a brief introduction to eight key points of the flow meter installation:

1. The external environment requirements:


The flow meter is best installed indoors. We must take sunscreen, rain, lightning protection measures if we must installed it outdoors so as not to affect its service life. Flow meter should be installed in a site that is convenient maintenance, no strong electromagnetic interference, and heat radiation.

2. The requirements of the bypass pipe:


The cut-off valve (stop valve) should be installed before and after the pipeline of the flow meter while the bypass pipe should also be set in order to ensure that the flow meter maintenance does not affect the normal production. Flow control valve should be installed in the downstream of the flow meter and the upper valve of the flow meter must be fully open when being used, to avoid the phenomenon that the fluid of the upstream part flows unsteady.

3. Requirements for straight pipe segments:


The flow meter must be installed horizontally on the pipe (the pipe is tilted within 50). When installing, the flow meter axis should be concentric with the pipeline axis and the flow direction should be consistent. If the installation site allows the proposed upstream straight pipe segment 20D, downstream of 5D, then the length of flow meter upstream pipe should be not less than 2D straight pipe. The inner diameter of the upstream and downstream piping for the flow meter mounting point must be the same as that of the flow meter's.

4. The media contains impurities requirements:


In order to ensure the service life of the flow meter, the filter should be installed before the straight pipe section of the flow meter.

5. The installation of welding requirements:


When installing flow meter (such as Vortex flow meter), the user needs another pair of standard flange welding on the front and back pipes. Welding with a flow meter is not allowed! When installing, the gasket between the flanges cannot be recessed into the pipe. Before installing flow meter, we should strictly remove the dirt from the pipe. such as debris, welding slag, stone, dust, etc. The automatic filter of 5-micron sieve is recommended to install in the upstream to block the droplets and sand. It is best to use a pipe with an equal diameter (or by-pass) instead of a flow meter for purging to ensure that the flow meter would not be damaged during being used.

6. Flow meter grounding requirements:


The flow meter should be grounded reliably and cannot be shared with the ground wire of the strong electric system.

7. Requirements for the explosion-proof product:


In order to ensure the normal and safe use of the flow meter (such as electromagnetic flow meter), the user should check that if the using environment of explosion-proof flow meter meets the requirements of the user explosion-proof. And in the process of the installation and usage,  the user should strictly follow the using requirements of the national explosion-proof product. The user is not allowed to change the explosion-proof system connection mode nor feel free to open the instrument 

8. Requirements for the flow range:


Selection in the specified flow range to prevent speeding operation. It ensures to get the ideal accuracy and normal service life.


Description of Electromagnetic Flowmeter

Electromagnetic flowmeter is a kind of inductional instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.
Magnetic inductive flow meter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Mag meter is industrial flow meter; it can be used in environmental protection, metallurgy, pharmaceutical, paper making, water supply (magnetic water meter) etc.
Besides measuring flow of general conductive liquid, magnet meter can measure flow of liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali to be used as chemical flow meter, sanitary flow meter or sewage flow meter. We are supplier for full bore  electromagnetic flow meter.
As China magnetic flow meter manufacturer, the magnetic flow meter price is reasonable, custom magnetic meter also with fast delivery time due to abundant flow meter spare parts in our warehouse.

Electromagnetic Flowmeter Technical Parameters




Picture
full bore magnetic flow meter
electromagnetic flow meter
magmeter flow meter
electromagnetic flow sensor
Model
SE 11
Standard
SE12
High Accuracy
SE13
Sanitary
SE14
Insertion type
Medium
Conductivity Fluids
Accuracy
±0.5%
±0.25%
±0.5%
±1.5%
Repeatability
±0.25%
±0.125%
±0.25%
±0.75%
Fluid Temperature
-25°C ~ 130 °C
-25°C ~ 130 °C
-25°C ~ 130 °C
-25°C ~ 130 °C
Conductivity
≥ 5μs/cm ( soft water should be ≥ 20μs/cm)
Size
10~2000 mm
10~2000 mm
10~125 mm
200~3000 mm
Operation Pressure
0.6Mpa/1.0Mpa/1.6Mpa/2.5Mpa/4.0Mpa/Others
Velocity
0.5 m/s ~ 10 m/s
Flow Direction
Forward / Reversed
Electrodes Material
316L / Hastelloy C2,B4/Tantalum/Titanium/Platinoiridita/others
Liner Material
Rubber /PTFE/PFA
PFA
PTFE
Electrodes Type
Standard
Qty of Electrodes
2 pairs
( one pair for measuring, one pair for grounding)
1pair ( measuring)
Tube Material
304 Stainless Steel
Flange Material
Carbon steel/304 Stainless steel
304 Stainless steel
304 Stainless steel
Installation Type
Flange
Tri-clamp/screw
Flange/plug-in
Protection level
IP65/P68 ( Remote Version)
Power
220VAC ±20% 60HZ  /  24 VDC
Signal Output
4~20mA
Communication
Hart / Modbus/ Profibus
Electrical connection
2* M20 * 1.5
Explosive-Proof
Exd eia II C T3~T6
Construction Type
Compact / Remote
Operation Environment
Magnetic flow meters Operation
Environment temperature:-25 °C~ + 60 °C; Relative Humility: 5% ~90%

Electromagnetic Flowmeter Flow Range

Size(DN)
Pressure
Min flow range
velocity(0-0.5)m/s
Max Flow range
velocity(0-10)m/s
10
4.0 Mpa
(0-2.25)L/min
(0-45)L/min
15
4.0 Mpa
(0-5)L/min
(0-100)L/min
20
4.0 Mpa
(0-7.5)L/min
(0-150)L/min
25
4.0 Mpa
(0-10L)/min
(0-200)L/min
32
4.0 Mpa
(0-20L)/min
(0-400)L/min
40
4.0 Mpa
(0-30L)/min
(0-600)L/min
50
4.0 Mpa
(0-3)m³/h
(0-60)m³/h
65
4.0 Mpa
(0-6)m³/h
(0-120)m³/h
80
4.0 Mpa
(0-9)m³/h
(0-180)m³/h
100
1.6 Mpa
(0-12)m³/h
(0-240)m³/h
125
1.6 Mpa
(0-21)m³/h
(0-420)m³/h
150
1.6 Mpa
(0-30)m³/h
(0-600)m³/h
200
1.6 Mpa
(0-54)m³/h
(0-1080)m³/h
250
1.6 Mpa
(0-90)m³/h
(0-1800)m³/h
300
1.0 Mpa
(0-120)m³/h
(0-2400)m³/h
350
1.0 Mpa
(0-165)m³/h
(0-3300)m³/h
400
1.0 Mpa
(0-225)m³/h
(0-4500)m³/h
500
1.0 Mpa
(0-330)m³/h
(0-6600)m³/h
600
1.0 Mpa
(0-480)m³/h
(0-9600)m³/h
700
1.0 Mpa
(0-660)m³/h
(0-13200)m³/h
800
1.0 Mpa
(0-900)m³/h
(0-18000)m³/h
900
1.0 Mpa
(0-1200)m³/h
(0-24000)m³/h
1000
1.0 Mpa
(0-1350)m³/h
(0-27000)m³/h
1200
0.6 Mpa
(0-2100)m³/h
(0-42000)m³/h
1400
0.6 Mpa
(0-2700)m³/h
(0-54000)m³/h
1600
0.6 Mpa
(0-3600)m³/h
(0-72000)m³/h
1800
0.6 Mpa
(0-4500)m³/h
(0-90000)m³/h
2000
0.6 Mpa
(0-5700)m³/h
(0-114000)m³/h

Electromagnetic Flowmeter Model Selection


Item
Code
Description
Factory Mark
SHD
Silver Automation Instruments
Meter Type
SE11
Standard ( 0.5% accuracy ,DN10~DN2000)
SE12
High Accuracy (0.25% accuracy,DN10~DN2000)
SE13
Sanitary type (0.5% accuracy,DN10~DN125,Tri-clamp )
SE14
Insertion type  (1.5% accuracy,DN200~3000)
Meter Size
-XXX
Example:100=DN100,refer to Table 2 Nominal diameter,
pressure and flow range
Electrode Material
E0
316L SS
E1
Hastelloy B
E2
Hastelloy C
E3
Titanium
E4
Tantalum
E5
Pt/Iridium Alloy
Liner Material
L1
Teflon (PTFE)
L2
F46 (FEP)
L3
PFA
L4
Hard rubber
Rated Pressure
1G
GB1.6Mpa
1D
DIN PN16
1A
ANSI 150#
2G
GB2.5Mpa
2D
DIN PN25
2A
ANSI 300#
3G
GB4.0Mpa
3D
DIN PN40
3A
ANSI 600#
S
Special
Working Temperature
E
<60 °C
H
60~160 °C
Protection Grade
P0
IP65
P1
IP 67
P2
IP68  (only for remote version, sensor IP68,converter IP65)
Converter Type
0
Compact
1
Remote (standard cable 5 meters)
Output
Signal Communication
S0
4~20mA
S1
RS-485
S2
Hart
S3
Profibus-DP*1
S4
Pulse Output
Housing Material
H0
Carbon steel
H1
304 SS
H2
Special Demand
Material of Body Flange
F0
Carbon steel
F1
304 SS
F2
Special Demand
Power Supply
G0
220V AC (85~265V,45~63 Hz)
G1
24V DC (18~36V)
G2
Battery supply (without 4~20mA output)
Explosion Proof
0
Non(0 could be omitted)
Ex
Exd eia II C T3~T6

Welcome to send your specific parameters to us, we will evaluate and choose proper type magnetic flow meter and provide best electromagnetic flow meter price to you.

评论

此博客中的热门博文

The Model Selection of Mag Meter& Mag Flow Meter Price

What applications do flow meters usually used?

Coriolis mass flow meters for batch sucrose solution Applications