General Introduction about Gas Turbine Flow Meters


1.Application

The gas turbine flowmeter integrates the gas turbine flow sensor and the gas flow totalizer in one body. The main technical performances of Silver Automation Instruments have reached the international level. The gas turbine flowmeter is used in petroleum, chemical, electric power, metallurgical industry, boiler, gas metering, gas pressure regulating station and gas meter for custody transfer
2.Working principle

When the air flow enters the flowmeter, it first passes through a specially structured straightener and accelerates. Under the action of the fluid, the turbine blade is at an angle to the fluid flow direction. At this time, the turbine generates a rotational moment, and the turbine starts to rotate after overcoming the resistance torque and the friction torque. When the moments reach the equilibrium elbow, the rotational speed is stable, and the rotational angular velocity of the turbine is linear with the flow rate. The magnet on the rotating transmitting disk periodically changes the reluctance of the eccentric, thereby inducing a flow volume flow with the fluid at both ends of the sensor. The pulse signal, which is amplified, filtered, shaped and then is sent to the converter for processing, the totalizer directly showing the volume flow and volume of the fluid.
3. Gas Turbine Flow Meter Construction





4.Flow meter Types

Thread Connection Gas Turbine Flow meter



Flange Connection Gas turbine Flow meter


5. Technical Specifications
5.1 Max Pressure loss at Normal Flow Range
Size (mm)Normal Flow Range (m3/h)Max Pressure Loss (Kpa)
20S2月20日1.5
25S4-401.5
40S6-651.5
50S17-701.2
S210-1001.4
80S113-2501
S220-4002
100S120-4001
S232-6501.5
150S150-10001
S280-16002
200S180-16000.8
S2130-25001.5
250S1130-25000.8
S2200-40002
300S200-40001
350S400-80001.5
400S650-130002
Accuracy1.5%(1.0%is available upon request)
Note: Max Pressure loss is the pressure loss of the air flow meter when working at the max flow point, medium is air at normal temperature.

5.2General Specifications
MediumClean gas at a low or middle flow rate
StandardMeasurement of gas flow in closed pipes-Turbine flowmeter (GB/T1 8940-2003)
Size& Process ConnectionFlangeStainless steel bodyDN20-DN300
Carbon steel bodyDN350,DN400
ThreadStainless steel bodyDN20,DN25,DN40,DN50
Flange StandardStandardGB/T9113-2000
OptionANSI, JIS ,DIN
ThreadStandardBSPP(male)
OptionBSPP(F),NPT.,etc

5.3 Pressure Rating of Gas Turbine Sensor
ConnectionMaterialSizeNormal Pressure RatingOption
FlangeStainless steelDN20-DN1001.6Mpa≤6.3Mpa
DN150-DN200≤4.0Mpa
DN250-DN300≤2.5Mpa
Carbon steelDN250-DN400-
ThreadStainless steelDN20-DN50≤4.0Mpa
5.4 Gas turbine meter Material
TypeBodyRotor
Thread304 Stainless steelAluminum alloy
(DN20-DN50)
Flange304 Stainless steelCarbon Steel
(DN20-DN300)(DN350,DN400)


Note:

Straightener Material: DN20-DN150 ,ABS, DN200 Cast aluminum alloy

Gas meter Transmitter Housing: Cast Aluminum Alloy
5.5 Electrical Specifications
Power SupplyDC24V3.6Vlithium battery
Consumption< 2W< 700μA
Protection levelIP65
Explosion ProofExd IICT6 Gb
Electrical PortM20*1.5 (F)
5.6. Operation Environment of Gas Turbine Flow Transmitter
Calibration ConditionCalibration Equipment1.Master Meter calibration facility
2.Sonic nozzle gas flow calibration facility
3.Bell prover gas calibration facility
EnvironmentTemperature: 20℃
Relative Humidity: 75%
OperationMedium temperature: -20 ~80℃
Atmospheric pressure: 86Kpa-106Kpa
Environment temperature:-20 ~60℃
Relative Humidity5%-90%

评论

发表评论

此博客中的热门博文

The Model Selection of Mag Meter& Mag Flow Meter Price

What applications do flow meters usually used?

Coriolis mass flow meters for batch sucrose solution Applications