Buy Differential Pressure Transmitter
Below is the process instruments list we need from silver automation instruments.kindly carefully check the technical specifications and choose proper type instruments and quote for us.
Table of items
Item. no.
|
Product/features
|
MU
|
Quantity
|
Diferential pressure digital programmable
transmitter, static pressure 330barg, power supply 24Vcc 2-wire, output signal
4-20mA, Hart protocol, measuring range programmed with Hart Communicator 375
|
|||
1
|
Δp=20000 mmH2O
|
pcs
|
2
|
2
|
Δp=10000 mmH2O
|
pcs
|
2
|
3
|
Δp=6000 mmH2O
|
pcs
|
2
|
4
|
Δp=3000 mmH2O
|
pcs
|
2
|
5
|
Δp=2500 mmH2O
|
pcs
|
2
|
6
|
Pressure transducer type EJX 110A
(Yokogawa), absolute pressure 0,4-20barg, Δp=10kPa, or similar
|
pcs
|
1
|
we want to buy China Diferential pressure transmitter, explosion-proof construction (type EEx d);
material of flanges, body, connectors, caps, isolation membrane - carbon
steel/AISI 316; filling fluid - silicon oil; process connection by external
thread G1/2''; cable gland material - SS; material of gaskets in contact with
measured fluid - PTFE (teflon);isolation ball valve for horizontal pipe; digital
display in mA; class 1; bracket and accesorries for mounting on 2'' pipe
|
|||
7
|
0-500
mmH2O; static
pressure 310 barg; measuring range limits setted to 0-500mmH2O
|
pcs
|
2
|
8
|
0-2.500mmH2O; static
pressure 310 barg; measuring range limits setted to 0-2500mmH2O
|
pcs
|
3
|
9
|
0-6.000mmH2O; static
pressure 310 barg; measuring range limits setted to 0-6000mmH2O
|
pcs
|
1
|
10
|
0-10.000mmH2O; static
pressure 420 barg; measuring range limits setted to 0-10000 mmH2O
|
pcs
|
1
|
11
|
0-20.000mmH2O; static
pressure 420 barg; measuring range limits setted to 0-20.000 mmH2O
|
pcs
|
3
|
Diferential
pressure transmitter, manufactured by Rosemount, or similar, with Hart protocol, compatible communicator 375
Rosemount, programmable range, static pressure 310barg, accuracy class 0,1% from
measuring range, with possibility to set local zero and span, digital display
in mA, class 1, output current 4-20 mA, with linear and squareroot output, explosion-proof
construction (type EEx d), body material - SS, filling fluid - silicon, gaskets
material in contact with fluid measured - PTFE (teflon), process conection by
external thread G1/2, ingress
protection IP 66/IP 67, cable gland by
SS, ambient temperature: -10 ÷ +50ºC, with density compensation.
|
|||
12
|
0-6000mmH2O
|
pcs
|
1
|
13
|
Diferential
pressure transmitter type Rosemount, or
similar, with Hart protocol (extractor included), programmable range,
Hmax = 1773,5mbar, static pressure = 250barg, accuracy class 0,1 from measuring
range, current output=4-20mA, process connection 1/2'' NPT, power supply =
24Vcc, temperature = -30÷80ºC
|
pcs
|
1
|
14
|
Diferential
pressure transmitter, Hmax = 295,18mbar, static pressure = 40barg, accuracy
class 0,1 from measuring range, current output=4-20mA, process connection
1/2'' NPT, range = 0÷250t/h, power supply = 24Vcc,
temperature
= -30 ÷80ºC, with local display
|
pcs
|
3
|
15
|
Diferential
pressure transmitter type Rosemount, with Hart protocol, model 3095 or similar, Hmax = 1568,2mbar, static
pressure = 250barg, accuracy class 0,1 from measuring range, current output
=4-20mA, power supply = 24Vcc
|
pcs
|
1
|
Gauge pressure
transmitter, explosion-proof construction (type EEx d); body material
SS X1.471; process connection by external thread G1/2''; cable gland made by
SS; isolation ball valve for horizontal pipe; digital display in mA; class 1;
bracket and accesorries for mounting on 2'' pipe
|
|||
16
|
0-1000 mbar; limits
of the measuring range 0-1000mbar
|
pcs
|
2
|
17
|
0-3 bar; limits of
the measuring range 0-3 bar
|
pcs
|
4
|
18
|
0-10 bar; limits of
the measuring range 0-10 bar
|
pcs
|
1
|
19
|
0-25 bar; limits of
the measuring range 0-25 bar
|
pcs
|
2
|
20
|
0-40 bar; limits of
the measuring range 0-40bar
|
pcs
|
3
|
21
|
0-250 bar; limits
of the measuring range 0-250 bar
|
pcs
|
7
|
22
|
0-300 bar; limits
of the measuring range 0-300 bar
|
pcs
|
2
|
Gauge pressure transmitter, manufacturer
Rosemount, or similar,with Hart protocol;
compatibile comunicator 375 Rosemount;
programmable range; static pressure 310barg, accuracy class 0,1 from measuring range; with
possibility to set local zero and span; digital dispaly in mA, class 1, output
current 4-20mA, process conection by external thread G1/2, ingress protection IP 66/IP 67, cable gland by SS
|
|||
23
|
0-40 bar
|
pcs
|
1
|
Gauge pressure transmitter
for NAOH-50% solution, with separation membrane, output signal 4-20mA; with
Hart protocol; accuracy class 1% from measuring point; process connection by
external thread 3/4'' NPT. Materials: body
from PVDF, or similar, to resist at NaOH-50% solution; ceramic membrane with
PTFE layer ; gaskets from FPM. Power supply 24Vcc, 2-wires; working temperature
-30ºC...+85ºC (transmitter must be compatible with device Signet 8250 - 2P)
|
|||
24
|
type Signet
3-2450-2L (0-10 bar), or similar
|
pcs
|
1
|
Level transmitter, radar
type, working fluid for antenna - atmosphere with acids or bases, pH 2-14, working
fluid - waters with traces of acids or bases pH 2-14; power supply 24Vcc; Hart protocol, display local digital
LCD, mounting place – tank roof, process connection G1 1/2, accuracy class
0,2%, ingress protection IP 68,
ambient temperature
-15ºC…+70 ºC;
|
|||
25
|
Vegaplus 61 sau
Vegason 62 ( 0-10m) or similar
|
pcs
|
1
|
评论
发表评论